JUMA - JOINT USE MASTARM POLE
HOME > SERVICES > TRAFFIC SIGNALS > CONTROLLERS > JUMA – JOINT USE MASTARM POLE
JUMA - JOINT USE MASTARM POLE
Features
- Outreach lengths of 3m, 4m, 5m, 6.5m
- Street light outreach lengths of 1.5m, 2m, 2.5m, 3m, 4m, 5m
- Multiple mounting heights of streetlights available
- Mastarm curve formed on a former so no distortion of pipe
- Ground plant , cage and flange mount options
- All lugs for all options of mounting lanterns comes standard
- Street light panel access hatch at base of pole
BENEFITS
- Ability to rotate mastarm for overheight loads
- If pole damaged in accident able to replace pole and reuse arm
- Ability to change height of streetlights or add camera mounting or barrier mounting by changing street light extension
Download PDF
Features
FUNCTIONALITY
From 4 to to 32 Signal “Groups” outputs are supported.
Up to 32 vehicle detector inputs.
Up to 32 external inputs (pedestrians, emergency vehicle, railway inputs).
Provision for pedestrian demand indicator displays.
Provision for one daily event output turn “No Right Turn Sign” On.
Communications ready for connection to SCATS.
WAN capability using TCP/IP
TIMING FUNCTIONS
- Time-settings are user defined and intersection specific.
- Time-settings include variable minimum green, ability to count vehicles arriving on red, variable.
- Timers monitor the input from vehicle detectors, indicating traffic density, and generate appropriate times to ensure efficient use of available green time.
- Pedestrian timers provide safe time settings for pedestrian and bicycle movements.
TRAFFIC SIGNAL DISPLAY
- Solid state switching of all signal groups.
- Capable of managing up to 1200 watts per signal group
- Capable of controlling incandescent, quartz halogen and LED signal lanterns
- Lamp fault monitoring feature with reporting functions for maintenance
- Last Red” feature for safety
- Flashing yellow failsafe display
- Ability to dim lanterns at night
SAFETY MONITORING AND REPORTING SYSTEMS
- Controller “watchdog” software monitoring system.
- Separate hardware and software conflict monitors
- Plain language message log
- All equipment and network malfunctions logged
LAPTOP USER INTERFACE
Unique software that uses a menu driven windows based system to display:
- Fault Error Log
- Group/Phasing Display
- Real Time Graphical Intersection Display
- Detector Diagnostics
- View SCATS Communications
- Lamp loads for each signal group
- Dimming and Regulation Details
- External Inputs and Auxiliary Outputs
- Personality Prom Details
- Group Flash in Maintenance Mode
- iPAQPDAcompatible
- OptionalHandHeldTerminal(HHT)
POWER FEATURES
- Capable of operating in a range from 110 to 240 volts (50 or 60Hz)
- Low mains voltage shutdown protection
- Designed to withstand over voltage conditions
- Designed for generator or UPS operating conditions
- Voltage regulation feature